NSN 6145-00-450-0477
Electric Cable
Round cross sectional shape, -40.0 degrees celsius and 75.0 degrees celsius tempurature rating, 0.680 inches cross section outside diameter, conductor quantity: 3.
Manufacturer part number CO-03HOF(3/12)SJ0680 for national stock number 6145004500477.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-450-0477.
-
MPN or Model
CO-03HOF(3/12)SJ0680
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
1 lb -
Cross Sectional Shape
Round -
Tempurature Rating
-40.0 degrees celsius and 75.0 degrees celsius -
Cross Section Outside Diameter
0.680 inches -
Conductor Quantity
3 -
Strand Quantity Per Conductor
65 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
12 awg all conductors -
Strand Awg Size Per Conductor
30 all conductors -
Conductor Arrangement And Quantity
3 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Material
Copper core conductor all conductors -
Material Specification
Qq-w-343, soft federal specification single material response core conductor all conductors -
Surface Treatment
Tin core conductor all conductors
More from these suppliers
- 5905-00-001-8511 MPN MILR39007-11Inductive Wire Wound Fixed Resistor
- 5905-00-004-6041 MPN MILR39005-6Noninductive Wire Wound Fixed Resistor
- 5905-00-004-6044 MPN RBR71L456R1BRNoninductive Wire Wound Fixed Resistor
- 5905-00-005-2898 MPN RNR60E1780FPFilm Fixed Resistor
- 5905-00-005-2951 MPN RNC60J2673BSFilm Fixed Resistor
- 5905-00-006-6984 MPN MIL-R-55182/3Film Fixed Resistor
- 5905-00-006-6987 MPN RNC60K5761FMFilm Fixed Resistor
- 5905-00-007-7197 MPN MILR55182-3Film Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-450-0477 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
CO-03HOF(3/12)SJ0680 | Military Specifications |
MIL-C-3432 | Military Specifications |