NSN 6145-00-471-0422
Electric Cable
Primary insulation conforms to l-p-403 type 3.
Manufacturer part number E12C0-9STX for national stock number 6145004710422.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-471-0422.
-
MPN or Model
E12C0-9STX
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Cross Sectional Shape
Round -
Tempurature Rating
-65.0 degrees celsius and 200.0 degrees celsius -
Cross Section Outside Diameter
0.284 inches -
Conductor Quantity
2 -
Strand Quantity Per Conductor
19 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
12 awg all conductors -
Strand Awg Size Per Conductor
25 all conductors -
Conductor Arrangement And Quantity
2 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Color
White 2nd position cover second conductor -
Material
Silver 2nd position shield braid, metallic cable -
Material Specification
Astm b298 assn standard single material response core conductor all conductors -
Precious Material And Location
Surface all conductors silver and shield, braid silver -
Precious Material
Silver -
Surface Treatment
Silver core conductor all conductors -
Surface Treatment Specification
Astm b298 assn standard single treatment response core conductor all conductors
More from these suppliers
- 6145-00-113-3911 MPN TX26-734CWElectrical Wire
- 5935-00-001-5883 MPN M81511-01E18-38PElectrical Receptacle Connector
- 5905-00-006-6950 MPN MILR39007-11Inductive Wire Wound Fixed Resistor
- 5905-00-009-6408 MPN MIL-R-55182/1Film Fixed Resistor
- 5905-00-009-6476 MPN MIL-R-39017/5Film Fixed Resistor
- 5935-00-020-7902 MPN MIL-C-81703Electrical Receptacle Connector
- 5905-00-027-0347 MPN MILR26-5Inductive Wire Wound Fixed Resistor
- 5930-00-044-3518 MPN MIL-S-83731Toggle Switch
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-471-0422 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
E12C0-9STX | Military Specifications |
MIL-C-55021/2 | Military Specifications |
9116C2002-12EN0-9S | Bae Systems Information And |
2SRTE1925AJV | Rscc Wire & Cable Llc |
2HX12-1925SV | Ericsson Inc |
EC12U0-9STX | Military Specifications |
MIL-C-55021/3 | Military Specifications |
9116C2002-12EN0-9S | Lockheed Corp |
MIL-DTL-55021/2 | Military Specifications |