NSN 6145-00-613-4475
Electric Cable
Five strands of no.31 awg steel reinforcement per cond.
Manufacturer part number 9072327 for national stock number 6145006134475.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-613-4475.
-
MPN or Model
9072327
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
1 lb -
Cross Sectional Shape
Round -
Tempurature Rating
-65.0 degrees fahrenheit and 125.0 degrees fahrenheit -
Cross Section Outside Diameter
1.100 inches -
Conductor Quantity
39 -
Strand Quantity Per Conductor
41 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
18 awg all conductors -
Strand Awg Size Per Conductor
34 all conductors -
Conductor Arrangement And Quantity
35 singles and 2 twisted pair -
Conductor Grouping Arrangement Type And Quantity
2 twisted pair all groups -
Conductor Sequence Within Groups
Third conductor second group and fourth conductor second group -
Material
Copper core conductor all conductors -
Surface Treatment
Tin core conductor all conductors
More from these suppliers
- 5905-00-072-0617 MPN 11031525-1Nonprecision Nonwire Wound Variable Resistor
- 5905-00-088-0417 MPN 9984423-47Noninductive Wire Wound Fixed Resistor
- 5905-00-124-7339 MPN MIS-16286Inductive Wire Wound Fixed Resistor
- 5975-00-179-0098 MPN 10336599AElectrical Box Connector
- 5985-00-241-6701 MPN 8515626Waveguide Horn
- 5935-00-258-0138 MPN 10105834Electrical Receptacle Connector
- 5935-00-259-0257 MPN 9177012Tip Plug
- 4820-00-288-7334 MPN 8014660Globe Valve
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-613-4475 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
9072327 | U S Army Aviation And Missile |
3071-1018P1 | Raytheon Company |