NSN 6145-00-617-1362
Electric Cable
Round cross sectional shape, -55.0 degrees celsius and 75.0 degrees celsius tempurature rating, 0.860 inches cross section outside diameter, conductor quantity: 12.
Manufacturer part number CO-12HLF(12/16)0860 for national stock number 6145006171362.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-617-1362.
-
MPN or Model
CO-12HLF(12/16)0860
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
1 lb -
Cross Sectional Shape
Round -
Tempurature Rating
-55.0 degrees celsius and 75.0 degrees celsius -
Cross Section Outside Diameter
0.860 inches -
Conductor Quantity
12 -
Strand Quantity Per Conductor
65 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
16 awg all conductors -
Strand Awg Size Per Conductor
34 all conductors -
Conductor Arrangement And Quantity
12 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Material
Rubber butadiene-styrene class sbr and rubber chloroprene class cr 1st position jacket cable -
Material Specification
Qq-w-343, soft federal specification single material response core conductor all conductors -
Surface Treatment
Tin core conductor all conductors -
Surface Treatment Specification
Astm b33-63 assn standard single treatment response core conductor all conductors
More from these suppliers
- 5935-00-068-4676 MPN 691C906P1Electrical Receptacle Connector
- 5950-00-078-0637 MPN PL7014878G8Radio Frequency Coil
- 5945-00-080-3706 MPN CR2810E11AB1B4Electromagnetic Relay
- 5905-00-100-4959 MPN K7880394REV1Inductive Wire Wound Fixed Resistor
- 5905-00-120-2175 MPN PL147C993PC17Composition Fixed Resistor
- 5940-00-155-7045 MPN K7110740REV4PT2Terminal Board
- 5940-00-156-7363 MPN T5994271PC26Lug Terminal
- 5940-00-164-4205 MPN T8672508PC2Terminal Board
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-617-1362 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
CO-12HLF(12/16)0860 | Military Specifications |
MIL-C-3432 | Military Specifications |
CW1293 | General Electric Co |
CW1293-12C0NDUCT0R | General Electric Co |