NSN 6145-00-643-0013
Electric Cable
Round cross sectional shape, -55.0 degrees celsius and 75.0 degrees celsius tempurature rating, 0.405 inches cross section outside diameter, conductor quantity: 2.
Manufacturer part number CO-02MLF(2/16)0405 for national stock number 6145006430013.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-643-0013.
-
MPN or Model
CO-02MLF(2/16)0405
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.1 lb -
Cross Sectional Shape
Round -
Tempurature Rating
-55.0 degrees celsius and 75.0 degrees celsius -
Cross Section Outside Diameter
0.405 inches -
Conductor Quantity
2 -
Strand Quantity Per Conductor
65 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
16 awg all conductors -
Strand Awg Size Per Conductor
34 all conductors -
Conductor Arrangement And Quantity
2 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Color
White 2nd position cover second conductor -
Material
Rubber butadiene-styrene class sbr and rubber chloroprene class cr 1st position jacket cable -
Material Specification
Qq-w-343, soft federal specification single material response core conductor all conductors -
Surface Treatment
Tin core conductor all conductors
More from these suppliers
- 5905-00-001-2971 MPN RLR05C912GMFilm Fixed Resistor
- 5905-00-004-0189 MPN MILR39005-5Noninductive Wire Wound Fixed Resistor
- 5905-00-005-2497 MPN RNC55H9311FPFilm Fixed Resistor
- 5905-00-006-5570 MPN MIL-R-39017/5Film Fixed Resistor
- 5905-00-006-5574 MPN RNR60H8661FMFilm Fixed Resistor
- 5905-00-007-9111 MPN RNR60J1622BSFilm Fixed Resistor
- 5905-00-009-8032 MPN MILR55182-3Film Fixed Resistor
- 5905-00-009-8036 MPN RNC65K1101FSFilm Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-643-0013 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
CO-02MLF(2/16)0405 | Military Specifications |
MIL-C-3432 | Military Specifications |
211-159 | Columbia Scientific Corp |