Electric Cable
Round cross sectional shape, 0.920 inches cross section outside diameter, 8 conductors, strand quantity per conductor: 19 all conductors.
Manufacturer part number 10178192 for national stock number 6145006574755.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-657-4755.
-
MPN or Model
10178192
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.3 lb -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
0.920 inches -
Conductor Quantity
8 -
Strand Quantity Per Conductor
19 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
16 awg all conductors -
Strand Awg Size Per Conductor
29 all conductors -
Conductor Sequence Within Groups
Fourth conductor first group and fifth conductor first group and sixth conductor first group -
Voltage Rating
18000.0 root mean square (rms) operating voltage all conductors -
Material
Copper core conductor all conductors -
Material Specification
Qq-w-343, soft federal specification single material response core conductor all conductors -
Surface Treatment
Tin core conductor all conductors
More from these suppliers
- 5905-00-043-5185 MPN 10127954Precision Wire Wound Variable Resistor
- 5950-00-151-4263 MPN 8106700Reactor
- 5985-00-223-3042 MPN 10670747-3Fixed Attenuator
- 5905-00-242-2292 MPN 9002953Film Fixed Resistor
- 5950-00-491-8939 MPN 10110455-008Radio Frequency Coil
- 5950-00-519-7963 MPN 8136948Reactor
- 5930-00-549-0206 MPN 9968171Push Switch
- 5905-00-556-3350 MPN 8192120Nonprecision Nonwire Wound Variable Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-657-4755 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
10178192 | U S Army Aviation And Missile |
I2903 | Draka Cableteq Usa Inc |
I2903L008 | Draka Cableteq Usa Inc |