NSN 6145-00-823-2008
Electric Cable
Round cross sectional shape, 60.0 degrees celsius tempurature rating, 0.420 inches cross section outside diameter, conductor quantity: 3.
Manufacturer part number UL 62 for national stock number 6145008232008.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-823-2008.
-
MPN or Model
UL 62
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.1 lb -
Cross Sectional Shape
Round -
Tempurature Rating
60.0 degrees celsius -
Cross Section Outside Diameter
0.420 inches -
Conductor Quantity
3 -
Strand Quantity Per Conductor
65 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
16 awg all conductors -
Strand Awg Size Per Conductor
34 all conductors -
Conductor Arrangement And Quantity
3 singles -
Voltage Rating
600.0 ac rated working voltage all conductors -
Color
Green 3rd position cover third conductor -
Material
Plastic 1st position primary insulation all conductors -
Material Specification
Qq-w-343, soft federal specification single material response core conductor all conductors
More from these suppliers
- 5975-00-280-3197 MPN ANSI UL6Electrical Conduit Nipple
- 5975-00-898-9882 MPN ANSI UL514BElectrical Conduit Nipple
- 5930-00-051-4448 MPN W-S-896/2Toggle Switch
- 4820-00-476-5341 MPN WWV58Gate Valve
- 5905-00-489-2223 MPN RNC50H3162FSFilm Fixed Resistor
- 5935-01-284-8411 MPN WC596/212-1Electrical Receptacle Connector
- 5305-00-010-5718 MPN FFS111Wood Screw
- 5305-00-012-2394 MPN FFS85TYPE2STYLE10PHexagon Head Cap Screw
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-823-2008 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
UL 62 | Underwriters Laboratories Inc. |
UL62ST6BCK3/16PVCPVC | Underwriters Laboratories Inc. |
J-C-580ST6CK3/16TTJ | Federal Specifications |
JC580TYPEST | Federal Specifications |