NSN 6145-00-836-8157
Electric Cable
Round cross sectional shape, 75.0 degrees celsius tempurature rating, 0.750 inches cross section outside diameter, conductor quantity: 7.
Manufacturer part number THW06CF7-10TPJ for national stock number 6145008368157.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-836-8157.
-
MPN or Model
THW06CF7-10TPJ
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
Cross Sectional Shape
Round -
Tempurature Rating
75.0 degrees celsius -
Cross Section Outside Diameter
0.750 inches -
Conductor Quantity
7 -
Tracer Color
Black first tracer seventh conductor -
Strand Quantity Per Conductor
7 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
10 awg all conductors -
Strand Awg Size Per Conductor
18 all conductors -
Conductor Arrangement And Quantity
7 singles -
Voltage Rating
600.0 dc rated working voltage all conductors -
Color
White 7th position cover fourth conductor -
Material
Plastic polyvinyl chloride 1st position jacket cable -
Material Specification
Qq-w-343 federal specification single material response core conductor all conductors -
Surface Treatment
Tin core conductor all conductors
More from these suppliers
- 5940-00-393-0657 MPN AA-59126/06Stud Terminal
- 5940-01-535-4163 MPN A-A-59125/2Terminal Board
- 5940-01-394-5262 MPN A-A-59126/12Stud Terminal
- 5305-00-833-8655 MPN A-A-55624-31Machine Screw
- 6145-00-466-2599 MPN A-A-59544Electrical Wire
- 6145-01-346-7877 MPN AA59569R30T1125Wire Braid
- 6145-01-464-9305 MPN A-A-59544Electrical Wire
- 6145-01-602-8772 MPN A-A-59551-S30S1PElectrical Wire
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-836-8157 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
THW06CF7-10TPJ | Federal Specifications |
A-A-59544 | Federal Commercial Item Description |
JC30 | Federal Specifications |