NSN 6145-00-839-3895
Electric Cable
Primary insulation conforms to l-p-403 type 3.
Manufacturer part number E16C9-90U for national stock number 6145008393895.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-839-3895.
-
MPN or Model
E16C9-90U
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.1 lb -
Cross Sectional Shape
Twist -
Tempurature Rating
-65.0 degrees celsius and 200.0 degrees celsius -
Cross-sectional Height
0.080 inches -
Cross-sectional Width
0.160 inches -
Conductor Quantity
2 -
Tracer Color
Black single tracer second conductor -
Strand Quantity Per Conductor
19 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
16 awg all conductors -
Strand Awg Size Per Conductor
29 all conductors -
Conductor Arrangement And Quantity
2 twisted together w/no outer covering -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Color
White 1st position primary insulation all conductors -
Material
Plastic polytetrafluoroethylene 1st position primary insulation all conductors -
Material Specification
Astm b298 assn standard single material response core conductor all conductors -
Precious Material And Location
Surface all conductors silver -
Precious Material
Silver -
Surface Treatment
Silver core conductor all conductors -
Surface Treatment Specification
Astm b298 assn standard single treatment response core conductor all conductors
More from these suppliers
- 5905-00-001-8493 MPN RWR89S52R3FRInductive Wire Wound Fixed Resistor
- 5905-00-004-6092 MPN RNC60H7680FMFilm Fixed Resistor
- 5905-00-005-2664 MPN RBR71L42201BMNoninductive Wire Wound Fixed Resistor
- 5905-00-005-2895 MPN RNC70H1961FRFilm Fixed Resistor
- 5905-00-009-1133 MPN MILR55182-1Film Fixed Resistor
- 5905-00-009-6542 MPN RNC70H64R9FSFilm Fixed Resistor
- 5905-00-012-3045 MPN RWR74S7320FRInductive Wire Wound Fixed Resistor
- 5905-00-039-6133 MPN RP101TG502KKNonprecision Wire Wound Variable Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-839-3895 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
E16C9-90U | Military Specifications |
MIL-C-55021/2 | Military Specifications |
TEH2XAWG16/19/E-CU.VS-9+90 | Hew-kabel Gmbh |
EC16U9-90U | Military Specifications |
MIL-DTL-55021/2 | Military Specifications |