NSN 6145-00-909-0614
Electric Cable
Round cross sectional shape, 105.0 degrees celsius tempurature rating, 0.220 inches cross section outside diameter, conductor quantity: 2.
Manufacturer part number 2019690-4 for national stock number 6145009090614.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-909-0614.
-
MPN or Model
2019690-4
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
3 lb -
Cross Sectional Shape
Round -
Tempurature Rating
105.0 degrees celsius -
Cross Section Outside Diameter
0.220 inches -
Conductor Quantity
2 -
Strand Quantity Per Conductor
19 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
18 awg all conductors -
Strand Awg Size Per Conductor
30 all conductors -
Conductor Arrangement And Quantity
2 singles -
Voltage Rating
1000.0 root mean square (rms) operating voltage all conductors -
Color
White 2nd position cover second conductor -
Material
Plastic polyvinyl chloride 1st position primary insulation all conductors -
Material Specification
Qq-w-343, soft federal specification single material response core conductor all conductors -
Surface Treatment
Tin core conductor all conductors -
Reference Number Differentiating Characteristics
Navord od36190
More from these suppliers
- 5905-00-061-2559 MPN 2243237P4Precision Wire Wound Variable Resistor
- 5935-00-075-8036 MPN 1961045-1Connector
- 5905-00-080-4641 MPN 59A5A170-6Film Fixed Resistor
- 5935-00-089-8787 MPN 1277072-3Plug-in Electronic Components Socket
- 5945-00-098-8938 MPN 2892647-3Solid State Relay
- 5905-00-100-4049 MPN 212695-15ALT49Inductive Wire Wound Fixed Resistor
- 5905-00-132-2284 MPN 62A114C35-3Thermal Resistor
- 5940-00-156-7134 MPN 351979PC5Lug Terminal
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-909-0614 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
2019690-4 | Navair And Navsea Managed |