NSN 6145-00-917-2342
Electric Cable
Outer jacket color black.
Manufacturer part number MCOS-7 for national stock number 6145009172342.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-917-2342.
-
MPN or Model
MCOS-7
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Cross Sectional Shape
Round -
Tempurature Rating
80.0 degrees celsius -
Cross Section Outside Diameter
0.585 inches -
Conductor Quantity
7 -
Tracer Color
Black first tracer seventh conductor -
Strand Quantity Per Conductor
16 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
18 awg all conductors -
Strand Awg Size Per Conductor
30 all conductors -
Conductor Arrangement And Quantity
7 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Color
White 7th position cover fourth conductor -
Material
Plastic polyvinyl chloride 1st position primary insulation all conductors -
Material Specification
Astm b3 assn standard single material response core conductor all conductors
More from these suppliers
- 5905-00-003-5787 MPN RWR89S1911FRInductive Wire Wound Fixed Resistor
- 5905-00-004-6054 MPN RER60F33R2PInductive Wire Wound Fixed Resistor
- 5905-00-005-8956 MPN MILR55182-6Film Fixed Resistor
- 5905-00-006-6944 MPN MILR55182-6Film Fixed Resistor
- 5905-00-007-0695 MPN RBR56L182R0BRNoninductive Wire Wound Fixed Resistor
- 5905-00-008-0361 MPN RBR52L22101FRNoninductive Wire Wound Fixed Resistor
- 5905-00-009-2981 MPN RNC70K30R1FSFilm Fixed Resistor
- 5905-00-009-2996 MPN RNC55J5232BMFilm Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-917-2342 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
MCOS-7 | Military Specifications |
MIL-C-915/11 | Military Specifications |
Stock Check
- NS: 6
- NE: 10