NSN 6145-01-005-2379
Electric Cable
Optional identification on method 1 applies.
Manufacturer part number MIL-C-27500 for national stock number 6145010052379.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-005-2379.
-
MPN or Model
MIL-C-27500
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.1 lb -
Cross Sectional Shape
Twist -
Tempurature Rating
200.0 degrees celsius -
Cross-sectional Height
0.141 inches -
Cross-sectional Width
0.141 inches -
Conductor Quantity
3 -
Strand Quantity Per Conductor
19 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
16 awg all conductors -
Strand Awg Size Per Conductor
29 all conductors -
Conductor Arrangement And Quantity
3 twisted together w/no outer covering -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Material
Copper core conductor all conductors -
Material Specification
Astm b298 assn standard single material response core conductor all conductors -
Precious Material And Location
Surface single conductor silver -
Precious Material
Silver -
Surface Treatment
Silver core conductor all conductors -
Surface Treatment Specification
Astm b298 assn standard single treatment response core conductor all conductors -
Departure From Cited Document
As modified by basic body color per conductor
More from these suppliers
- 5935-00-135-4250 MPN 201A082-3Electrical Connector Potting Mold
- 5975-01-125-6238 MPN 209M840-19AElectrical Conduit Adapter
- 5935-01-217-0910 MPN BAR-54-AB00-1004Electrical Connector Backshell
- 5935-01-291-4454 MPN TXR40MAB00-1412AIJElectrical Connector Backshell
- 5975-01-346-2074 MPN TRO4AI-TINEL-LOCK-RINGElectrical Bonding Ring
- 5935-01-346-2126 MPN TXR40AB90-2416AI2Electrical Connector Backshell
- 5940-01-543-5397 MPN S02-07RConductor Splice
- 5930-01-609-0248 MPN 102A994-3/42-8Nonluminous Switch Actuator Cover
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-005-2379 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
MIL-C-27500 | Military Specifications |
M27500A16MW3U00 | Military Specifications |
88A0831-16-2-4-6 | Tyco Electronics Corporation |
7891145-3-16 | Boeing Company, The |