NSN 6145-01-006-9525
Electric Cable
Round cross sectional shape, 200.0 degrees celsius tempurature rating, 0.075 inches cross section outside diameter, conductor quantity: 2.
Manufacturer part number NEMA WC27500 for national stock number 6145010069525.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-006-9525.
-
MPN or Model
NEMA WC27500
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Cross Sectional Shape
Round -
Tempurature Rating
200.0 degrees celsius -
Cross Section Outside Diameter
0.075 inches -
Conductor Quantity
2 -
Strand Quantity Per Conductor
19 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
16 awg all conductors -
Strand Awg Size Per Conductor
29 all conductors -
Conductor Arrangement And Quantity
2 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Color
Blue 2nd position cover second conductor -
Surface Treatment
Nickel core conductor all conductors -
Surface Treatment Specification
Astm b355 assn standard single treatment response core conductor all conductors
More from these suppliers
- 6145-00-059-8825 MPN M27500-22RC1S04Electrical Special Purpose Cable
- 6145-00-116-7810 MPN NEMA HP3Electrical Wire
- 6145-00-417-6051 MPN HP3-ETXBCB6Electrical Wire
- 6145-00-937-8406 MPN MW16CHX000012Electrical Wire
- 6145-01-012-2557 MPN M27500-26ML1T08Electrical Special Purpose Cable
- 6145-01-014-6260 MPN NEMA WC27500Electrical Special Purpose Cable
- 6145-01-091-7011 MPN NEMA-HP3Electrical Wire
- 6145-01-120-5623 MPN M27500-20MH1T08Electrical Special Purpose Cable
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-006-9525 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
NEMA WC27500 | National Electrical Mfrs Assn |
M27500-16MY2N12 | National Electrical Mfrs Assn |
M7078/12-16-2 | Military Specifications |
MIL-C-7078/12 | Military Specifications |