NSN 6145-01-059-3662
Electric Cable
Optional identification method two applies.
Manufacturer part number M27500B8SA1A06 for national stock number 6145010593662.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-059-3662.
-
MPN or Model
M27500B8SA1A06
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.1 lb -
Cross Sectional Shape
Round -
Tempurature Rating
200.0 degrees celsius -
Conductor Quantity
1 -
Strand Quantity Per Conductor
133 single conductor -
Conductor Form
Stranded single conductor -
Round Conductor Size
8 awg single conductor -
Strand Awg Size Per Conductor
29 single conductor -
Conductor Arrangement And Quantity
1 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage single conductor -
Color
White 1st position jacket cable -
Material
Copper core conductor single conductor -
Material Specification
Astm b298 assn standard single material response core conductor single conductor -
Precious Material And Location
Surfase single conductor silver -
Precious Material
Silver -
Surface Treatment
Silver core conductor single conductor -
Surface Treatment Specification
Astm b298 assn standard single treatment response core conductor all conductors -
Departure From Cited Document
As modified by basic body color per conductor
More from these suppliers
- 4920-00-015-1633 MPN AF32-24002-501TDAircraft Maintenance Fixture
- 1560-00-108-5427 MPN 53-34036-97Aircraft Access Cover
- 1560-00-116-6279 MPN 32-32205-7Aircraft Structural Component Fitting
- 5945-00-134-5556 MPN 32-76163-1REVJElectromagnetic Relay
- 1680-00-138-6300 MPN 68J818043And St Brake Handle
- 1560-00-162-0553 MPN 53-90216-3Small Arms-fragmentation Protective Supplemental Armor
- 1560-00-232-4077 MPN 32-11004-416Support Tee
- 1560-00-234-7448 MPN 32-58291-307Aircraft Access Cover
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-059-3662 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M27500B8SA1A06 | Military Specifications |
MIL-C-27500 | Military Specifications |
ST5M1298-8S1S6 | Boeing Company, The |
10139934 | Nimikkeistokeskus Ncb Finland |