NSN 6145-01-061-3047
Electric Cable
Round cross sectional shape, -20.0 degrees celsius and 60.0 degrees celsius tempurature rating, 0.390 inches cross section outside diameter, conductor quantity: 2.
Manufacturer part number J-C-580SOCF2/18RNJ for national stock number 6145010613047.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-061-3047.
-
MPN or Model
J-C-580SOCF2/18RNJ
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.1 lb -
Cross Sectional Shape
Round -
Tempurature Rating
-20.0 degrees celsius and 60.0 degrees celsius -
Cross Section Outside Diameter
0.390 inches -
Conductor Quantity
2 -
Strand Quantity Per Conductor
19 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
18 awg all conductors -
Strand Awg Size Per Conductor
30 all conductors -
Conductor Arrangement And Quantity
2 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Color
White core conductor first conductor -
Material
Rubber chloroprene class cr 1st position jacket cable
More from these suppliers
- 5975-00-839-9753 MPN WC586AConduit Outlet
- 5975-00-913-2313 MPN WF408Electrical Conduit Bushing
- 5975-01-376-4656 MPN W-C-1094Electrical Conduit Adapter
- 5930-00-081-3611 MPN NDSCL2DN2SNBX1-60A240VAC250VDCBox Switch
- 5975-00-518-1733 MPN WF406Electrical Box Connector
- 5305-00-010-0881 MPN FFS92Machine Screw
- 5305-00-017-1575 MPN FFS107TYPECSSTYLE1STapping Screw
- 5305-00-042-0613 MPN FFS92Machine Screw
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-061-3047 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
J-C-580SOCF2/18RNJ | Federal Specifications |
J-C-580 | Federal Specifications |
1934 | Alpha Wire Corporation |
UL62 | Underwriters Laboratories Inc. |
UL62SOOW6BCF2/18EPCPE | Underwriters Laboratories Inc. |