NSN 6145-01-070-2155
Electric Cable
Round cross sectional shape, -20.0 degrees celsius and 60.0 degrees celsius tempurature rating, 0.305 inches cross section outside diameter, conductor quantity: 2.
Manufacturer part number UL62 for national stock number 6145010702155.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-070-2155.
-
MPN or Model
UL62
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.1 lb -
Cross Sectional Shape
Round -
Tempurature Rating
-20.0 degrees celsius and 60.0 degrees celsius -
Cross Section Outside Diameter
0.305 inches -
Conductor Quantity
2 -
Strand Quantity Per Conductor
16 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
18 awg all conductors -
Strand Awg Size Per Conductor
30 all conductors -
Conductor Arrangement And Quantity
2 singles -
Voltage Rating
300.0 root mean square (rms) operating voltage all conductors -
Color
White 2nd position cover second conductor -
Material
Rubber 1st position primary insulation all conductors
More from these suppliers
- 6145-00-418-2700 MPN 8623Electrical Power Cable
- 6145-01-280-6138 MPN 85230Electrical Special Purpose Cable
- 6145-01-360-1229 MPN 9553Electrical Power Cable
- 6145-01-386-3564 MPN 9934Electrical Special Purpose Cable
- 6145-01-415-8698 MPN 9912-5 GREENElectrical Wire
- 5975-01-032-4636 MPN ANSI UL1242Rigid Metal Conduit
- 5940-00-238-8539 MPN SCA547TYPETM148Lug Terminal
- 5975-00-284-6429 MPN WW-C-566Flexible Metal Conduit
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
![Mechanic Bill explains Electric Cable](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 6145-01-070-2155 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
UL62 | Underwriters Laboratories Inc. |
19227 | Belden Wire & Cable Company Llc |
1932 | Alpha Wire Corporation |
UL62SJOOW3BCF2/18EPCPE | Underwriters Laboratories Inc. |
J-C-580 | Federal Specifications |
J-C-580SJO3CF2/18RNJ | Federal Specifications |
Stock Check
![](/public/images/partscage_shelf3.png)