NSN 6145-01-147-0839
Electric Cable
Round cross sectional shape, 0.490 inches cross section outside diameter, 7 conductors, strand quantity per conductor: 19 all conductors.
Manufacturer part number 3006-6468 for national stock number 6145011470839.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-147-0839.
-
MPN or Model
3006-6468
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.1 lb -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
0.490 inches -
Conductor Quantity
7 -
Strand Quantity Per Conductor
19 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
12 awg all conductors -
Strand Awg Size Per Conductor
25 all conductors -
Conductor Arrangement And Quantity
7 singles -
Voltage Rating
1000.0 root mean square (rms) operating voltage all conductors -
Material
Rubber chloroprene class cr 1st position jacket cable -
Material Specification
Astm b33 assn standard single material response core conductor all conductors -
Surface Treatment
Tin core conductor all conductors -
Surface Treatment Specification
Astm b33-63 assn standard single treatment response core conductor all conductors
More from these suppliers
- 5905-00-061-4011 MPN 554630-200Nonprecision Wire Wound Variable Resistor
- 5950-00-088-8603 MPN 666213-096REVCPulse Transformer
- 4920-00-140-8397 MPN A75535-001Termination Adapter
- 5935-00-201-5312 MPN 641053Tip Jack Assembly
- 5930-00-461-5489 MPN V00052-001Switch Assembly
- 5930-00-548-4056 MPN D5791Sensitive Switch
- 5950-00-727-4843 MPN 666231-061Radio Frequency Transformer
- 5905-01-396-4570 MPN 6010187-003Inductive Wire Wound Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-147-0839 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
3006-6468 | Calmont Engineering & Electronics |
ABC 2491 | Glenair Inc. |
77034-2 | Falmat, Inc. |
6010716-002 | Bae Systems Information And |
6010716-002 | Lockheed Martin Corporation |