NSN 6145-01-173-3782
Electric Cable
Sixth grouping arrangement through forty-fourth grouping arrangement tenth conductor through one hundred thirty-second conductor.
Manufacturer part number 3SUS-44 for national stock number 6145011733782.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-173-3782.
-
MPN or Model
3SUS-44
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
3 lb -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
1.980 inches -
Conductor Quantity
132 -
Strand Quantity Per Conductor
7 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
18 awg all conductors -
Strand Awg Size Per Conductor
26 all conductors -
Conductor Arrangement And Quantity
44 triples -
Conductor Sequence Within Groups
Seventh conductor third group and eighth conductor third group and ninth conductor third group -
Color
Gray 1st position jacket cable -
Material
Copper core conductor all conductors -
Material Specification
Astm b3 assn standard single material response core conductor all conductors
More from these suppliers
- 5905-00-006-6986 MPN RNC60K5491FMFilm Fixed Resistor
- 5905-00-006-9159 MPN MIL-R-55182/3Film Fixed Resistor
- 5905-00-007-7290 MPN MILR55182-5Film Fixed Resistor
- 5905-00-007-7395 MPN MILR55182-1Film Fixed Resistor
- 5905-00-007-7405 MPN RTH22ES121TThermal Resistor
- 5905-00-008-8255 MPN RER70F19R6MInductive Wire Wound Fixed Resistor
- 5905-00-009-7983 MPN RER50F34R8RNoninductive Wire Wound Fixed Resistor
- 5905-00-012-4017 MPN RLR20C114GRFilm Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-173-3782 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
3SUS-44 | Military Specifications |