NSN 6145-01-201-9057
Electric Cable
Round cross sectional shape, 0.660 inches cross section outside diameter, 2 conductors, strand quantity per conductor: 7 all conductors.
Manufacturer part number LSDRW for national stock number 6145012019057.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-201-9057.
-
MPN or Model
LSDRW
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.1 lb -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
0.660 inches -
Conductor Quantity
2 -
Strand Quantity Per Conductor
7 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
14 awg all conductors -
Strand Awg Size Per Conductor
22 all conductors -
Conductor Arrangement And Quantity
2 singles -
Voltage Rating
3000.0 root mean square (rms) operating voltage all conductors -
Color
Black 1st position jacket cable -
Material
Plastic cross-linked polyolefin 1st position jacket cable -
Material Specification
Astm b3 assn standard single material response core conductor all conductors
More from these suppliers
- 5905-00-004-6105 MPN RNC65J1822FSFilm Fixed Resistor
- 5905-00-005-2678 MPN RER65FR143RInductive Wire Wound Fixed Resistor
- 5935-00-005-2818 MPN MILC83723-24Electrical Plug Connector
- 5905-00-005-8930 MPN RNC50H1003FPFilm Fixed Resistor
- 5905-00-005-8932 MPN RNC65H3011FRFilm Fixed Resistor
- 5905-00-006-5484 MPN RBR55L53001BRNoninductive Wire Wound Fixed Resistor
- 5905-00-009-4452 MPN RV6NAYSA104ANonprecision Nonwire Wound Variable Resistor
- 5905-00-009-8047 MPN MILR10509-3Film Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-201-9057 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
LSDRW | Military Specifications |
MIL-C-24643/53 | Military Specifications |
M24643/53-02UN | Military Specifications |
DRW | Military Specifications |
MIL-C-915/73 | Military Specifications |