NSN 6145-01-201-9059
Electric Cable
Round cross sectional shape, 0.660 inches cross section outside diameter, 8 conductors, strand quantity per conductor: 7 all conductors.
Manufacturer part number LS8NW6 for national stock number 6145012019059.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-201-9059.
-
MPN or Model
LS8NW6
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.5 lb -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
0.660 inches -
Conductor Quantity
8 -
Strand Quantity Per Conductor
7 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
12 awg all conductors -
Strand Awg Size Per Conductor
20 all conductors -
Conductor Arrangement And Quantity
8 singles -
Color
Black 1st position jacket cable -
Material
Plastic cross-linked polyolefin 1st position jacket cable -
Material Specification
Astm b3 assn standard single material response core conductor all conductors
More from these suppliers
- 5905-00-003-8281 MPN RLR07C682JPFilm Fixed Resistor
- 5905-00-004-6035 MPN MILR39005-6Noninductive Wire Wound Fixed Resistor
- 5905-00-004-6056 MPN RER65F18R2MInductive Wire Wound Fixed Resistor
- 5905-00-005-2668 MPN RBR71L50001BRNoninductive Wire Wound Fixed Resistor
- 5905-00-005-2883 MPN RNC55H9090FMFilm Fixed Resistor
- 5905-00-006-6950 MPN RWR89SR205FPInductive Wire Wound Fixed Resistor
- 5905-00-007-0734 MPN MILR18546-1Noninductive Wire Wound Fixed Resistor
- 5905-00-009-8030 MPN RNC60H6813FMFilm Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-201-9059 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
LS8NW6 | Military Specifications |
MIL-C-24643/54 | Military Specifications |
M24643/54-01UN | Military Specifications |