NSN 6145-01-201-9510
Electric Cable
Round cross sectional shape, 1.132 inches cross section outside diameter, 44 conductors, strand quantity per conductor: 7 all conductors.
Manufacturer part number M24643/18-08UD for national stock number 6145012019510.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-201-9510.
-
MPN or Model
M24643/18-08UD
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
4 lb -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
1.132 inches -
Conductor Quantity
44 -
Strand Quantity Per Conductor
7 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
18 awg all conductors -
Strand Awg Size Per Conductor
26 all conductors -
Conductor Arrangement And Quantity
44 singles -
Voltage Rating
1000.0 root mean square (rms) operating voltage all conductors -
Color
Black 1st position jacket cable -
Material Specification
Astm b3 assn standard single material response core conductor all conductors -
Surface Treatment
Tin alloy 3rd position coating cable
More from these suppliers
- 5905-00-001-5837 MPN MILR55182-7Film Fixed Resistor
- 5905-00-004-2059 MPN RBR56L16402BRNoninductive Wire Wound Fixed Resistor
- 5905-00-004-6118 MPN RNC55K1502FRFilm Fixed Resistor
- 5905-00-005-2653 MPN RBR56L22720BRNoninductive Wire Wound Fixed Resistor
- 5935-00-006-5423 MPN M83723/21R2219NElectrical Receptacle Connector
- 5905-00-006-7050 MPN RNR70C3651FPFilm Fixed Resistor
- 5905-00-007-7232 MPN MIL-R-39005/4Noninductive Wire Wound Fixed Resistor
- 5905-00-009-7982 MPN MIL-R-39008/5Composition Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-201-9510 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M24643/18-08UD | Military Specifications |
MIL-C-24643/18 | Military Specifications |
LSMSCS-44 | Military Specifications |