NSN 6145-01-201-9512
Electric Cable
Round cross sectional shape, 1.780 inches cross section outside diameter, 6 conductors, strand quantity per conductor: 61 all conductors.
Manufacturer part number M24643/19-02UN for national stock number 6145012019512.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-201-9512.
-
MPN or Model
M24643/19-02UN
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
4 lb -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
1.780 inches -
Conductor Quantity
6 -
Strand Quantity Per Conductor
61 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
00 awg all conductors -
Strand Awg Size Per Conductor
17 all conductors -
Conductor Arrangement And Quantity
6 singles -
Voltage Rating
1000.0 root mean square (rms) operating voltage all conductors -
Color
Black 1st position jacket cable -
Material
Plastic cross-linked polyolefin 1st position jacket cable -
Material Specification
Astm b3 assn standard single material response core conductor all conductors
More from these suppliers
- 5905-00-004-6055 MPN RER65FR169MInductive Wire Wound Fixed Resistor
- 5905-00-004-7643 MPN RBR71L30901BMNoninductive Wire Wound Fixed Resistor
- 5905-00-005-2697 MPN RNC55J6341FMFilm Fixed Resistor
- 5935-00-005-2827 MPN M83723/73R1831NElectrical Receptacle Connector
- 5905-00-005-8932 MPN RN65C3011FFilm Fixed Resistor
- 5905-00-006-5574 MPN RNC60H8661FMFilm Fixed Resistor
- 5905-00-007-3895 MPN MIL-R-39005/4Noninductive Wire Wound Fixed Resistor
- 5905-00-009-2966 MPN RNC60H1690FRFilm Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-201-9512 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M24643/19-02UN | Military Specifications |
MIL-DTL-24643/19 | Military Specifications |
LS6SGU-125 | Military Specifications |
MIL-C-24643/19 | Military Specifications |