NSN 6145-01-202-0675
Electric Cable
Round cross sectional shape, 1.960 inches cross section outside diameter, 4 conductors, strand quantity per conductor: 684 all conductors.
Manufacturer part number M24643/3-37UN for national stock number 6145012020675.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-202-0675.
-
MPN or Model
M24643/3-37UN
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
3.3 lb -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
1.960 inches -
Conductor Quantity
4 -
Strand Quantity Per Conductor
684 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
133 awg all conductors -
Strand Awg Size Per Conductor
27 all conductors -
Conductor Arrangement And Quantity
4 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Color
Green 4th position cover fourth conductor -
Material
Plastic cross-linked polyolefin 1st position jacket cable -
Material Specification
Astm b3 assn standard single material response core conductor all conductors
More from these suppliers
- 5905-00-001-7176 MPN RP251FD152KKNonprecision Wire Wound Variable Resistor
- 5905-00-004-6067 MPN RNC55C1212FSFilm Fixed Resistor
- 5905-00-005-2894 MPN RN65D6810GFFilm Fixed Resistor
- 5905-00-005-8956 MPN RNR70C2671FRFilm Fixed Resistor
- 5935-00-006-1240 MPN MILC83723-22Electrical Receptacle Connector
- 5905-00-006-5573 MPN MILR55182-3Film Fixed Resistor
- 5935-00-006-7153 MPN MIL-C-26482Electrical Receptacle Connector
- 5905-00-008-0361 MPN MILR93Noninductive Wire Wound Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-202-0675 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M24643/3-37UN | Military Specifications |
MIL-DTL-24643/3 | Military Specifications |
LSFHOF-133 | Military Specifications |
MIL-C-24643/3 | Military Specifications |