NSN 6145-01-202-2789
Electric Cable
Round cross sectional shape, 0.610 inches cross section outside diameter, 14 conductors, strand quantity per conductor: 26 all conductors.
Manufacturer part number M24643/7-03UN for national stock number 6145012022789.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-202-2789.
-
MPN or Model
M24643/7-03UN
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.5 lb -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
0.610 inches -
Conductor Quantity
14 -
Strand Quantity Per Conductor
26 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
16 awg all conductors -
Strand Awg Size Per Conductor
30 all conductors -
Conductor Arrangement And Quantity
14 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Color
Black 1st position jacket cable -
Material Specification
Astm b3 assn standard single material response core conductor all conductors
More from these suppliers
- 5905-00-001-5692 MPN MIL-R-93/3Noninductive Wire Wound Fixed Resistor
- 5905-00-001-7334 MPN RNR60J2001BSFilm Fixed Resistor
- 5905-00-004-5832 MPN MILR22097-5Nonprecision Nonwire Wound Variable Resistor
- 5905-00-004-6020 MPN MIL-R-3005/5Noninductive Wire Wound Fixed Resistor
- 5905-00-004-6025 MPN RBR56L57600BMNoninductive Wire Wound Fixed Resistor
- 5905-00-004-6077 MPN RNC60H1020FRFilm Fixed Resistor
- 5905-00-006-5502 MPN RNC60J4423BSFilm Fixed Resistor
- 5905-00-006-7100 MPN MIL-R-39009/1Inductive Wire Wound Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-202-2789 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M24643/7-03UN | Military Specifications |
MIL-DTL-24643/7 | Military Specifications |
LSMHOF-14 | Military Specifications |
MIL-C-24643/7 | Military Specifications |