Electric Cable
Round cross sectional shape, 0.771 inches cross section outside diameter, 2 conductors, strand quantity per conductor: 7 all conductors.
Manufacturer part number M24643/15-05UN for national stock number 6145012022798.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-202-2798.
-
MPN or Model
M24643/15-05UN
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.2 lb -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
0.771 inches -
Conductor Quantity
2 -
Strand Quantity Per Conductor
7 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
7 awg all conductors -
Strand Awg Size Per Conductor
15 all conductors -
Conductor Arrangement And Quantity
2 singles -
Voltage Rating
1000.0 root mean square (rms) operating voltage all conductors -
Color
White 2nd position cover second conductor -
Material Specification
Astm b3 assn standard single material response core conductor all conductors
More from these suppliers
- 5905-00-001-2880 MPN RV2NAYSB502CNonprecision Nonwire Wound Variable Resistor
- 5905-00-001-7379 MPN MIL-R-39005/2Noninductive Wire Wound Fixed Resistor
- 5905-00-004-0190 MPN RBR56L68000BMNoninductive Wire Wound Fixed Resistor
- 5905-00-004-7648 MPN MILR55182-1Film Fixed Resistor
- 5905-00-006-3006 MPN MIL-R-39005/4Noninductive Wire Wound Fixed Resistor
- 5905-00-006-9051 MPN MIL-R-55182/6Film Fixed Resistor
- 5905-00-007-0636 MPN MILR39005-5Noninductive Wire Wound Fixed Resistor
- 5905-00-009-1142 MPN MIL-R-39009/1Inductive Wire Wound Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-202-2798 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M24643/15-05UN | Military Specifications |
MIL-DTL-24643/15 | Military Specifications |
LSDSGU-23 | Military Specifications |
MIL-C-24643/15 | Military Specifications |