NSN 6145-01-202-3486
Electric Cable
Round cross sectional shape, 0.658 inches cross section outside diameter, 10 conductors, strand quantity per conductor: 7 all conductors.
Manufacturer part number MSCS-10 for national stock number 6145012023486.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-202-3486.
-
MPN or Model
MSCS-10
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.3 lb -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
0.658 inches -
Conductor Quantity
10 -
Strand Quantity Per Conductor
7 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
18 awg all conductors -
Strand Awg Size Per Conductor
26 all conductors -
Conductor Arrangement And Quantity
10 singles -
Voltage Rating
1000.0 root mean square (rms) operating voltage all conductors -
Color
Black 1st position jacket cable -
Material Specification
Astm b3 assn standard single material response core conductor all conductors -
Surface Treatment
Tin alloy 3rd position coating cable
More from these suppliers
- 5905-00-001-7334 MPN RNC60J2001BPFilm Fixed Resistor
- 5905-00-004-6013 MPN RBR55L21502BRNoninductive Wire Wound Fixed Resistor
- 5905-00-004-6059 MPN RER65F68R1MInductive Wire Wound Fixed Resistor
- 5905-00-004-6118 MPN MIL-R-55182/1Film Fixed Resistor
- 5905-00-009-2964 MPN RNR60H1132FMFilm Fixed Resistor
- 5905-00-012-3541 MPN MILR39005-4Noninductive Wire Wound Fixed Resistor
- 5935-00-012-5522 MPN MIL-C-26482Electrical Receptacle Connector
- 5905-00-018-0955 MPN RN55E1602BFilm Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-202-3486 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
MSCS-10 | Military Specifications |
M24643/18-02UD | Military Specifications |
MIL-C-24643/18 | Military Specifications |
LSMSCS-10 | Military Specifications |