NSN 6145-01-202-3492
Electric Cable
Round cross sectional shape, 1.126 inches cross section outside diameter, 2 conductors, strand quantity per conductor: 61 all conductors.
Manufacturer part number M24643/48-08UN for national stock number 6145012023492.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-202-3492.
-
MPN or Model
M24643/48-08UN
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
2.5 lb -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
1.126 inches -
Conductor Quantity
2 -
Strand Quantity Per Conductor
61 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
0 awg all conductors -
Strand Awg Size Per Conductor
18 all conductors -
Conductor Arrangement And Quantity
1 twisted pair -
Voltage Rating
1000.0 root mean square (rms) operating voltage all conductors -
Color
Black 1st position jacket cable -
Material
Plastic cross-linked polyolefin 1st position jacket cable -
Material Specification
Astm b3 assn standard single material response core conductor all conductors
More from these suppliers
- 5905-00-003-8266 MPN MILR39017-1EFilm Fixed Resistor
- 5905-00-004-6119 MPN RNR55K1541FPFilm Fixed Resistor
- 5905-00-005-2690 MPN RNR50H7500FSFilm Fixed Resistor
- 5905-00-005-2902 MPN RNC55H3012FPFilm Fixed Resistor
- 5905-00-006-5497 MPN MIL-R-10509/1Film Fixed Resistor
- 5905-00-007-0636 MPN MILR39005-5Noninductive Wire Wound Fixed Resistor
- 5935-00-007-7163 MPN MIL-C-5015Electrical Plug Connector
- 5905-00-007-7396 MPN RNCL043011FMFilm Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-202-3492 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M24643/48-08UN | Military Specifications |
MIL-DTL-24643/48 | Military Specifications |
LSDNW-100 | Military Specifications |
MIL-C-24643/48 | Military Specifications |