NSN 6145-01-202-6958
Electric Cable
Round cross sectional shape, 0.822 inches cross section outside diameter, 24 conductors, strand quantity per conductor: 7 all conductors.
Manufacturer part number MSCU-24 for national stock number 6145012026958.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-202-6958.
-
MPN or Model
MSCU-24
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.3 lb -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
0.822 inches -
Conductor Quantity
24 -
Strand Quantity Per Conductor
7 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
18 awg all conductors -
Strand Awg Size Per Conductor
26 all conductors -
Conductor Arrangement And Quantity
24 singles -
Voltage Rating
1000.0 root mean square (rms) operating voltage all conductors -
Color
Black 1st position jacket cable -
Material Specification
Astm b3 assn standard single material response core conductor all conductors
More from these suppliers
- 5905-00-001-2834 MPN RBR53L27122BRNoninductive Wire Wound Fixed Resistor
- 5905-00-004-2062 MPN MILR55182-6Film Fixed Resistor
- 5905-00-006-1225 MPN RLR05C2002GRFilm Fixed Resistor
- 5905-00-006-6940 MPN RNC60J1823BSFilm Fixed Resistor
- 5905-00-007-9081 MPN RBR55L882R3BRNoninductive Wire Wound Fixed Resistor
- 5905-00-012-1100 MPN MILR93-13Noninductive Wire Wound Fixed Resistor
- 5905-00-021-6259 MPN RCR07G115JMComposition Fixed Resistor
- 5905-00-023-8056 MPN RB52AE12001FInductive Wire Wound Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-202-6958 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
MSCU-24 | Military Specifications |
M24643/18-05UN | Military Specifications |
MIL-C-24643/18 | Military Specifications |
LSMSCU-24 | Military Specifications |
MIL-DTL-24643/18 | Military Specifications |
Stock Check