NSN 6145-01-202-6962
Electric Cable
Round cross sectional shape, 0.882 inches cross section outside diameter, 24 conductors, strand quantity per conductor: 7 all conductors.
Manufacturer part number M24643/18-05UD for national stock number 6145012026962.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-202-6962.
-
MPN or Model
M24643/18-05UD
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.6 lb -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
0.882 inches -
Conductor Quantity
24 -
Strand Quantity Per Conductor
7 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
18 awg all conductors -
Strand Awg Size Per Conductor
26 all conductors -
Conductor Arrangement And Quantity
24 singles -
Voltage Rating
1000.0 root mean square (rms) operating voltage all conductors -
Color
Black 1st position jacket cable -
Material Specification
Astm b3 assn standard single material response core conductor all conductors -
Surface Treatment
Tin alloy 3rd position coating cable
More from these suppliers
- 5905-00-004-6127 MPN RNR60J1333JMFilm Fixed Resistor
- 5905-00-004-7654 MPN RWR81S9000FMInductive Wire Wound Fixed Resistor
- 5905-00-005-2686 MPN RN65C4992FFilm Fixed Resistor
- 5905-00-009-9953 MPN RNC65H4322FMFilm Fixed Resistor
- 5905-00-011-6639 MPN RW37V682Inductive Wire Wound Fixed Resistor
- 5905-00-025-5932 MPN RTH42ES501KThermal Resistor
- 5905-00-031-3895 MPN RNC70H2610FSFilm Fixed Resistor
- 5905-00-043-4630 MPN RN60G1433FFilm Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-202-6962 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M24643/18-05UD | Military Specifications |
MIL-DTL-24643/18 | Military Specifications |
LSMSCS-24 | Military Specifications |
MIL-C-24643/18 | Military Specifications |