NSN 6145-01-203-6566
Electric Cable
Round cross sectional shape, 1.940 inches cross section outside diameter, 3 conductors, strand quantity per conductor: 61 all conductors.
Manufacturer part number LS5KVTSGU-150 for national stock number 6145012036566.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-203-6566.
-
MPN or Model
LS5KVTSGU-150
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
1.940 inches -
Conductor Quantity
3 -
Strand Quantity Per Conductor
61 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
000 awg all conductors -
Strand Awg Size Per Conductor
16 all conductors -
Conductor Arrangement And Quantity
3 singles -
Voltage Rating
5000.0 root mean square (rms) operating voltage all conductors -
Color
Black 1st position jacket cable -
Material
Plastic cross-linked polyolefin 1st position jacket cable -
Material Specification
Astm b3 assn standard single material response core conductor all conductors
More from these suppliers
- 5905-00-001-2880 MPN RV2NAYSB502CNonprecision Nonwire Wound Variable Resistor
- 5905-00-001-5700 MPN RBR55L27400FMNoninductive Wire Wound Fixed Resistor
- 5905-00-001-7222 MPN RN70G1274FFilm Fixed Resistor
- 5905-00-005-2675 MPN RBR71L95R82BMNoninductive Wire Wound Fixed Resistor
- 5905-00-005-8956 MPN RN70G2671FFilm Fixed Resistor
- 5905-00-006-2942 MPN RBR71L16501BMNoninductive Wire Wound Fixed Resistor
- 5905-00-008-2527 MPN MILR55182-1Film Fixed Resistor
- 5905-00-009-8038 MPN RNC70H1003FMFilm Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-203-6566 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
LS5KVTSGU-150 | Military Specifications |
MIL-DTL-24643/22 | Military Specifications |
M24643/22-02UN | Military Specifications |
MIL-C-24643/22 | Military Specifications |