NSN 6145-01-205-3633
Electric Cable
Sixth grouping arrangement eleventh and twelfthconductor through thirtieth grouping arrangement fifty-ninth and sixtieth conductor.
Manufacturer part number LS2SWU-30 for national stock number 6145012053633.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-205-3633.
-
MPN or Model
LS2SWU-30
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
2 lb -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
1.715 inches -
Conductor Quantity
60 -
Strand Quantity Per Conductor
7 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
18 awg all conductors -
Strand Awg Size Per Conductor
26 all conductors -
Conductor Arrangement And Quantity
30 twisted pair -
Conductor Grouping Arrangement Type And Quantity
30 twisted pair all groups -
Conductor Sequence Within Groups
Third conductor second group and fourth conductor second group -
Color
Black 1st position jacket cable -
Material
Plastic polyester 2nd position tape all groups -
Material Specification
Mil-i-631, type g military specification single material response 3rd position tape all groups -
Surface Treatment
Tin core conductor all conductors -
Surface Treatment Specification
Astm b33-63 assn standard single treatment response core conductor all conductors
More from these suppliers
- 5905-00-001-8516 MPN MIL-R-39009/2Noninductive Wire Wound Fixed Resistor
- 5930-00-004-0067 MPN MIL-S-3786/4Rotary Switch
- 5905-00-004-6024 MPN RBR56L51R10BMNoninductive Wire Wound Fixed Resistor
- 5905-00-004-6038 MPN RBR71L26951AMNoninductive Wire Wound Fixed Resistor
- 5905-00-004-6076 MPN MIL-R-55182/1Film Fixed Resistor
- 5905-00-006-5492 MPN MILR55182-3Film Fixed Resistor
- 5905-00-006-5558 MPN MIL-R-39009/1Inductive Wire Wound Fixed Resistor
- 5905-00-006-5572 MPN RNC60H1332FPFilm Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-205-3633 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
LS2SWU-30 | Military Specifications |
MIL-DTL-24643/33 | Military Specifications |
M24643/33-07UN | Military Specifications |
2SWU-30 | Military Specifications |
MIL-C-915/49 | Military Specifications |
MIL-C-24643/33 | Military Specifications |