NSN 6145-01-222-9192
Electric Cable
Twist cross sectional shape, 150.0 degrees celsius tempurature rating, 0.130 inches cross-sectional height, cross-sectional width: 0.130 inches .
Manufacturer part number NEMA WC27500 for national stock number 6145012229192.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-222-9192.
-
MPN or Model
NEMA WC27500
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.1 lb -
Cross Sectional Shape
Twist -
Tempurature Rating
150.0 degrees celsius -
Cross-sectional Height
0.130 inches -
Cross-sectional Width
0.130 inches -
Conductor Quantity
3 -
Tracer Color
Orange first tracer third conductor -
Strand Quantity Per Conductor
19 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
18 awg all conductors -
Strand Awg Size Per Conductor
30 all conductors -
Conductor Arrangement And Quantity
1 twisted together w/no outer covering -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Color
White 1st position cover all conductors -
Material
Plastic polyalkene 1st position primary insulation all conductors -
Material Specification
Astm b33 assn standard single material response core conductor all conductors -
Surface Treatment
Tin core conductor all conductors -
Surface Treatment Specification
Astm b33-63 assn standard single treatment response core conductor all conductors
More from these suppliers
- 6145-00-226-3675 MPN NEMA-HP3Electrical Wire
- 6145-00-581-1615 MPN HP3-EXBHB0Electrical Wire
- 6145-01-108-2612 MPN NEMA-HP3Electrical Wire
- 6145-01-356-3245 MPN M27500-24TN2N09Electrical Special Purpose Cable
- 6145-01-426-8866 MPN HP3-EWBLE2Electrical Wire
- 6145-01-456-6574 MPN NEMA HP3Electrical Wire
- 6145-01-457-1055 MPN NEMA HP3Electrical Wire
- 6145-01-474-8554 MPN M27500B10WR7G24Electrical Power Cable
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-222-9192 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
NEMA WC27500 | National Electrical Mfrs Assn |
M27500-18ML3U00 | National Electrical Mfrs Assn |
M27500-18ML3U00 | Military Specifications |
MIL-C-27500 | Military Specifications |