NSN 6145-01-231-3382
Electric Cable
Primary insulation and jacket material conform to l-p-403 type 3.
Manufacturer part number D-3037 for national stock number 6145012313382.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-231-3382.
-
MPN or Model
D-3037
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Cross Sectional Shape
Round -
Tempurature Rating
200.0 degrees celsius -
Cross Section Outside Diameter
0.284 inches -
Conductor Quantity
6 -
Strand Quantity Per Conductor
19 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
16 awg all conductors -
Strand Awg Size Per Conductor
29 all conductors -
Conductor Arrangement And Quantity
6 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Color
White 1st position jacket cable -
Material
Silver 2nd position shield braid, metallic cable -
Material Specification
Astm b298 assn standard single material response core conductor all conductors -
Precious Material And Location
Surface all conductors silver and surface shield braid silver -
Precious Material
Silver -
Surface Treatment
Silver core conductor all conductors -
Surface Treatment Specification
Astm b298 assn standard single treatment response core conductor all conductors
More from these suppliers
- 6145-01-523-3878 MPN 1100-109AREDElectrical Wire
- 5950-00-081-2145 MPN 809000-382Radio Frequency Transformer
- 5905-00-108-4820 MPN B7568PC59Nonprecision Wire Wound Variable Resistor
- 5905-00-141-1165 MPN 697052-682Composition Fixed Resistor
- 5950-00-200-9998 MPN 666230-345Radio Frequency Coil
- 5945-00-322-4018 MPN 350017-000Relay Contact Set
- 5935-00-557-4751 MPN 48368-000130-99Telephone Jack Assembly
- 5950-00-645-7241 MPN 648251-000Radio Frequency Coil
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-231-3382 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
D-3037 | Standard Wire & Cable Co. |
6011247-025 | Bae Systems Information And |