NSN 6145-01-241-5178
Electric Cable
Each single,twisted pair and quad has a tin coated copper braid shield and a plastic,polyester tape.
Manufacturer part number 5812212 for national stock number 6145012415178.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-241-5178.
-
MPN or Model
5812212
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
1.495 inches -
Conductor Quantity
67 -
Color Coding Document
5812212-53711 drawing -
Strand Quantity Per Conductor
19 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
16 awg all conductors -
Strand Awg Size Per Conductor
29 all conductors -
Conductor Arrangement And Quantity
2 twisted quad and 8 twisted pair and 43 singles -
Color
Gray 1st position jacket cable -
Material
Plastic polyalkene 1st position primary insulation all conductors -
Material Specification
Astm b33 assn standard single material response core conductor all conductors -
Surface Treatment
Tin core conductor all conductors -
Surface Treatment Specification
Astm b33-63 assn standard single treatment response core conductor all conductors
More from these suppliers
- 4820-00-186-3824 MPN 803-4384536-1SAGlobe Valve
- 5950-00-224-2042 MPN 221403PC13Electrical Coil
- 4820-00-375-8290 MPN 4824-3113750PC548621Case
- 5935-00-571-0086 MPN 3151913-6Electrical Connector Cover
- 5945-00-895-9739 MPN 3257640Electromagnetic Relay
- 5985-00-933-5299 MPN 2537969-2REVBWaveguide Assembly
- 5940-00-983-6052 MPN 1856938-11Terminal Board
- 5930-01-005-6476 MPN 803-1853048-1Rotary Switch
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-241-5178 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
5812212 | Naval Sea Systems Command |