NSN 6145-01-266-9237
Electric Cable
Twist cross sectional shape, 135.0 degrees celsius tempurature rating, 0.216 inches cross-sectional height, cross-sectional width: 0.432 inches .
Manufacturer part number BMX13-38A/1/2-8 for national stock number 6145012669237.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-266-9237.
-
MPN or Model
BMX13-38A/1/2-8
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.1 lb -
Cross Sectional Shape
Twist -
Tempurature Rating
135.0 degrees celsius -
Cross-sectional Height
0.216 inches -
Cross-sectional Width
0.432 inches -
Conductor Quantity
2 -
Strand Quantity Per Conductor
133 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
8 awg all conductors -
Strand Awg Size Per Conductor
29 all conductors -
Conductor Arrangement And Quantity
2 twisted together w/no outer covering -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Material
Plastic polyalkene 1st position primary insulation all conductors -
Material Specification
Astm b33 assn standard single material response core conductor all conductors -
Surface Treatment
Tin core conductor all conductors -
Surface Treatment Specification
Astm b33-63 assn standard single treatment response core conductor all conductors
More from these suppliers
- 1560-00-072-2267 MPN 65-35391-8Raceway Cover
- 1560-00-073-4238 MPN A02E2355-7Duct Assembly
- 1560-00-088-2011 MPN 25-2780-8Aircraft Structural Component Support
- 4820-00-135-5470 MPN 10-30440-1Check Valve
- 4920-00-356-9124 MPN 2TE65-73720-1Aircraft Maintenance Fixture
- 5935-00-415-5990 MPN STBM27G14Electrical Connector Potting Mold
- 1560-00-571-1916 MPN 5-85682-2Aircraft Structural Component Support
- 1560-00-608-3815 MPN 5-89875-56Aircraft Trailing Edge
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-266-9237 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
BMX13-38A/1/2-8 | The Boeing Company |