NSN 6145-01-274-3332
Electric Cable
Plastic,polyolefin is irradiated and cross-linked.
Manufacturer part number P30079/3-N030 for national stock number 6145012743332.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-274-3332.
-
MPN or Model
P30079/3-N030
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Cross Sectional Shape
Round -
Tempurature Rating
135.0 degrees celsius -
Cross Section Outside Diameter
0.815 inches -
Conductor Quantity
6 -
Strand Quantity Per Conductor
37 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
12 awg all conductors -
Strand Awg Size Per Conductor
28 all conductors -
Conductor Arrangement And Quantity
1 twisted quad and 1 twisted pair -
Conductor Sequence Within Groups
First conductor first group and second conductor first group and third conductor first group and fourth conductor first group -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Material
Plastic polyolefin 1st position primary insulation all conductors -
Material Specification
Astm b33 assn standard single material response core conductor all conductors -
Surface Treatment
Tin core conductor all conductors -
Surface Treatment Specification
Astm b33-63 assn standard single treatment response core conductor all conductors
More from these suppliers
- 6145-01-267-4211 MPN 14413-97-9Electrical Special Purpose Cable
- 6145-01-313-9872 MPN T-121351/14-3Electrical Wire
- 4920-00-141-8525 MPN F10007-1Hydraulic System Components Test Stand
- 1560-00-214-8491 MPN 6-52679-2Pilots Window Latch Detent
- 1560-00-320-4554 MPN 5-39886-55Main Cowling Handle
- 1560-00-547-2075 MPN 6-83582Emergency Pin Assembly
- 1560-00-621-4676 MPN 29-7671Wing Drain Elbow
- 1560-00-631-6185 MPN 5-86559-137Gap Wing Cover
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-274-3332 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
P30079/3-N030 | The Boeing Company |
12935 | Rscc Wire & Cable Llc |
T-10710 | General Cable Industries, Inc. |
12935 | Rscc Wire & Cable Llc |