NSN 6145-01-303-0999
Electric Cable
Round cross sectional shape, -65.0 degrees celsius and 200.0 degrees celsius tempurature rating, 0.246 inches cross section outside diameter, conductor quantity: 3.
Manufacturer part number EC16U9-0-2SF for national stock number 6145013030999.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-303-0999.
-
MPN or Model
EC16U9-0-2SF
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Cross Sectional Shape
Round -
Tempurature Rating
-65.0 degrees celsius and 200.0 degrees celsius -
Cross Section Outside Diameter
0.246 inches -
Conductor Quantity
3 -
Strand Quantity Per Conductor
19 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
16 awg all conductors -
Strand Awg Size Per Conductor
29 all conductors -
Conductor Arrangement And Quantity
1 triples -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Material
Plastic fluorinated ethylene propylene 2nd position jacket cable -
Material Specification
Astm b33 assn standard single material response core conductor all conductors -
Precious Material And Location
Surface all conductors silver and surface shield braid silver -
Precious Material
Silver -
Surface Treatment
Silver core conductor all conductors -
Surface Treatment Specification
Astm b298 assn standard single treatment response core conductor all conductors
More from these suppliers
- 6145-00-958-6013 MPN 75911-26-92Electrical Wire
- 6145-01-089-8851 MPN 75911-26-9267Electrical Wire
- 6145-01-235-8368 MPN ST5M1247F16-2SJElectrical Power Cable
- 6145-01-419-8403 MPN 5M2870-20C5NElectrical Special Purpose Cable
- 6145-01-420-6122 MPN 5M2870-24D5JElectrical Special Purpose Cable
- 6145-01-633-6524 MPN HN2N8A4NS24-9Electrical Special Purpose Cable
- 6145-01-355-0147 MPN LB-B1-0015Electrical Wire
- 6145-01-633-3623 MPN SMLH10A7Y24Electrical Special Purpose Cable
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-303-0999 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
EC16U9-0-2SF | Military Specifications |
MIL-C-5021/2 | Military Specifications |
A3004366-4 | Nexans Aerospace Usa Llc |
A3004366-4 | Barcel/cdt |
A3004366-4 | Us Army Communications & |
E16C9-0-2SF | Military Specifications |
MIL-DTL-55021/2 | Military Specifications |