NSN 6145-01-305-3882
Electric Cable
Cable contain 4 size 11 awg uninsulated tinned copper ground wires. Each ground wire is covered with a green braid..
Manufacturer part number M3432-04HDF(4/4-4/10R)1290 for national stock number 6145013053882.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-305-3882.
-
MPN or Model
M3432-04HDF(4/4-4/10R)1290
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.1 lb -
Cross Sectional Shape
Round -
Tempurature Rating
-55.0 degrees celsius and 75.0 degrees celsius -
Cross Section Outside Diameter
1.290 inches -
Conductor Quantity
4 -
Accessory Wire Type And Quantity
4 ground -
Strand Quantity Per Conductor
133 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
4 awg all conductors -
Strand Awg Size Per Conductor
27 all conductors -
Conductor Arrangement And Quantity
4 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Material
Rubber chloroprene class cr 1st position jacket cable -
Material Specification
Qq-w-343, soft federal specification single material response core conductor all conductors -
Surface Treatment
Tin core conductor all conductors
More from these suppliers
- 5905-00-001-7377 MPN MIL-R-39005/2Noninductive Wire Wound Fixed Resistor
- 5905-00-005-2884 MPN MILR55182-1Film Fixed Resistor
- 5905-00-006-7099 MPN RER50F56R2RNoninductive Wire Wound Fixed Resistor
- 5940-00-009-0169 MPN MIL-T-81349/2Sectional Terminal Junction Block
- 5935-00-013-9141 MPN MIL-C-28748Electrical Receptacle Connector
- 5905-00-024-0599 MPN RNC65J1180BSFilm Fixed Resistor
- 5905-00-026-9150 MPN MIL-R-22/5Nonprecision Wire Wound Variable Resistor
- 5905-00-027-6137 MPN MILR94-5Nonprecision Nonwire Wound Variable Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-305-3882 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M3432-04HDF(4/4-4/10R)1290 | Military Specifications |
MIL-DTL-3432 | Military Specifications |
CO-04HDF(4/4-4/10R)1290 | Military Specifications |
MIL-C-3432 | Military Specifications |
CO-04HDF(4/4-4/11R)1290 | Military Specifications |