NSN 6145-01-355-3715
Electric Cable
A double blue band shall be applied every 2 3/4 inches on basic wire.
Manufacturer part number MIL-C-7078/12 for national stock number 6145013553715.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-355-3715.
-
MPN or Model
MIL-C-7078/12
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
0.205 inches -
Conductor Quantity
4 -
Tracer Color
Blue single tracer second conductororange single tracer third conductorgreen single tracer fourth conductor -
Strand Quantity Per Conductor
19 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
16 awg all conductors -
Strand Awg Size Per Conductor
29 all conductors -
Conductor Arrangement And Quantity
4 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Material
Copper core conductor all conductors -
Material Specification
Astm b355 assn standard single material response core conductor all conductors -
Surface Treatment
Nickel core conductor all conductors -
Departure From Cited Document
As modified by outer jacket color and color bands on basic wire
More from these suppliers
- 6145-00-323-5921 MPN 35-50115Electrical Wire
- 6145-00-345-2565 MPN ST5M1247-26A1SJElectrical Special Purpose Cable
- 6145-01-077-7241 MPN 24E1936(SPCW)1CSTE-9Electrical Special Purpose Cable
- 6145-01-313-9837 MPN 37AA-0112-22-8Electrical Wire
- 6145-01-495-2631 MPN 5M2619-20-2SJElectrical Power Cable
- 6145-01-089-6136 MPN 75911-24-9248Electrical Wire
- 6145-01-310-9375 MPN LB-B1-2124Electrical Power Cable
- 6145-01-420-1828 MPN 5MD1-16E1-GJElectrical Power Cable
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-355-3715 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
MIL-C-7078/12 | Military Specifications |
B1-0134 | Nexans Aerospace Usa Llc |
LB-B1-5164 | Barcel/cdt |
16731/20079KK4 | Carlisle Interconnect Technologies, |
30-90499/16 | Champlain Cable Corp |