NSN 6145-01-428-4068
Electric Cable
Round cross sectional shape, -55.0 degrees celsius and 75.0 degrees celsius tempurature rating, 0.600 inches cross section outside diameter, conductor quantity: 4.
Manufacturer part number M3432-04HDF(4/14)0600 for national stock number 6145014284068.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-428-4068.
-
MPN or Model
M3432-04HDF(4/14)0600
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.6 lb -
Cross Sectional Shape
Round -
Tempurature Rating
-55.0 degrees celsius and 75.0 degrees celsius -
Cross Section Outside Diameter
0.600 inches -
Conductor Quantity
4 -
Strand Quantity Per Conductor
41 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
14 awg all conductors -
Strand Awg Size Per Conductor
30 all conductors -
Conductor Arrangement And Quantity
4 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Color
Green 1st position primary insulation third conductor -
Material
Rubber chloroprene class cr 2nd position jacket cable -
Material Specification
Qq-w-343 soft federal specification single material response core conductor all conductors -
Surface Treatment
Tin core conductor all conductors -
Surface Treatment Specification
Astm b33 assn standard single treatment response core conductor all conductors
More from these suppliers
- 5905-00-004-6076 MPN RNC55H2490FRFilm Fixed Resistor
- 5905-00-004-6094 MPN RNC60J1101BMFilm Fixed Resistor
- 5905-00-004-6149 MPN MILR26-5Inductive Wire Wound Fixed Resistor
- 5935-00-005-8862 MPN MILC83723-21Electrical Receptacle Connector
- 5905-00-006-2977 MPN RNC60H88R7FMFilm Fixed Resistor
- 5905-00-006-5497 MPN RN60C8111FFilm Fixed Resistor
- 5905-00-007-7197 MPN MILR55182-3Film Fixed Resistor
- 5905-00-008-0366 MPN MILR22097-4Nonprecision Nonwire Wound Variable Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-428-4068 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M3432-04HDF(4/14)0600 | Military Specifications |
MIL-DTL-3432 | Military Specifications |
CO-04HDF(4/14)0600 | Military Specifications |
MIL-C-3432 | Military Specifications |