NSN 6145-01-450-7347
Electric Cable
Round cross sectional shape, -40.0 degrees celsius and 75.0 degrees celsius tempurature rating, 0.353 inches cross section outside diameter, conductor quantity: 3.
Manufacturer part number M3432-03LGF 3/14 0353 for national stock number 6145014507347.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-450-7347.
-
MPN or Model
M3432-03LGF 3/14 0353
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Cross Sectional Shape
Round -
Tempurature Rating
-40.0 degrees celsius and 75.0 degrees celsius -
Cross Section Outside Diameter
0.353 inches -
Conductor Quantity
3 -
Strand Quantity Per Conductor
7 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
14 awg all conductors -
Strand Awg Size Per Conductor
19 all conductors -
Conductor Arrangement And Quantity
3 singles -
Voltage Rating
300.0 root mean square (rms) operating voltage all conductors -
Material
Rubber ethylene-propylene class epm 1st position primary insulation cable or rubber ethylene-propylene-diene class epdm 1st position primary insulation cable or rubber butadiene-styrene class sbr 1st position primary insulation cable
More from these suppliers
- 5905-00-003-7717 MPN RNC55H6040FSFilm Fixed Resistor
- 5905-00-004-6071 MPN MILR55182-1Film Fixed Resistor
- 5905-00-005-2659 MPN RBR71L11801BRNoninductive Wire Wound Fixed Resistor
- 5905-00-005-2799 MPN MILR22-2Nonprecision Wire Wound Variable Resistor
- 5905-00-005-2893 MPN RNC60K4640FPFilm Fixed Resistor
- 5905-00-006-5404 MPN MIL-R-39005/3Noninductive Wire Wound Fixed Resistor
- 5905-00-006-5494 MPN RNR60H2432FPFilm Fixed Resistor
- 5905-00-006-6985 MPN RNC60K3742FPFilm Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-450-7347 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M3432-03LGF 3/14 0353 | Military Specifications |
MIL-DTL-3432 | Military Specifications |
CO-03LGF(3/14)0353 | Military Specifications |