NSN 6145-01-474-8075
Electric Cable
Wire conforms to mil-w-22759/92; weapon system essential.
Manufacturer part number NEMA WC27500 for national stock number 6145014748075.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-474-8075.
-
MPN or Model
NEMA WC27500
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.1 lb -
Cross Sectional Shape
Round -
Tempurature Rating
260.0 degrees celsius -
End Application
F15a/b/c/d/e aircraft -
Conductor Quantity
4 -
Strand Quantity Per Conductor
37 all conductors -
Criticality Code Justification
Feat -
Conductor Form
Stranded all conductors -
Round Conductor Size
10.00 awg all conductors -
Strand Awg Size Per Conductor
26 all conductors -
Conductor Arrangement And Quantity
4 singles -
Voltage Rating
600.0 peak operating voltage all conductors -
Color
Yellow 1st position primary insulation third conductor -
Material
Plastic polytetrafluoroethylene 2nd position tape all conductors -
Surface Treatment
Nickel core conductor all conductors
More from these suppliers
- 6145-00-517-6666 MPN M27500-20VA1S06Electrical Special Purpose Cable
- 6145-00-681-1221 MPN HP3-EXBEB5Electrical Wire
- 6145-00-681-1520 MPN NEMA HP3Electrical Wire
- 6145-00-937-8634 MPN NEMA-1000Electrical Wire
- 6145-01-006-9383 MPN HP3-EXBGB937Electrical Wire
- 6145-01-027-6567 MPN NEMA-HP3Electrical Wire
- 6145-01-028-3802 MPN M27500-14A1T02Electrical Power Cable
- 6145-01-104-5076 MPN NEMA WC 27500Electrical Power Cable
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-474-8075 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
NEMA WC27500 | National Electrical Mfrs Assn |
M27500B10WR4U00 | National Electrical Mfrs Assn |
5MD1-10C4-UN | Boeing Company, The |
M27500B10WR4U00 | Military Specifications |
MIL-DTL-27500 | Military Specifications |