NSN 6145-01-475-1131
Electric Cable
Weapon system essential.
Manufacturer part number NEMA WC27500 for national stock number 6145014751131.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-475-1131.
-
MPN or Model
NEMA WC27500
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.1 lb -
Cross Sectional Shape
Round -
Tempurature Rating
-65.0 degrees celsius and 260.0 degrees celsius -
Cross Section Outside Diameter
Between 0.061 inches and 0.065 inches -
End Application
F15a/b/c/d/e -
Conductor Quantity
4 -
Strand Quantity Per Conductor
19 all conductors -
Criticality Code Justification
Feat -
Conductor Form
Stranded all conductors -
Round Conductor Size
18 awg all conductors -
Strand Awg Size Per Conductor
30 all conductors -
Color
Yellow core conductor third conductor -
Material
Plastic polytetrafluoroethylene 2nd position secondary insulation all conductors -
Surface Treatment
Nickel core conductor all conductors
More from these suppliers
- 6145-00-023-6941 MPN HP3-EXBBB8Electrical Wire
- 6145-00-548-0969 MPN NEMA HP3Electrical Wire
- 6145-00-937-8662 MPN MW016CTX000019UNCElectrical Wire
- 6145-01-055-4699 MPN M27500B22MW2U00Electrical Special Purpose Cable
- 6145-01-076-5066 MPN HP3-EEXBEE91Electrical Wire
- 6145-01-077-8736 MPN NEMA HP3Electrical Wire
- 6145-01-119-3171 MPN HP3-EXBFB06Electrical Wire
- 6145-01-132-6600 MPN NEMA WC27500Electrical Special Purpose Cable
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-01-475-1131 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
NEMA WC27500 | National Electrical Mfrs Assn |
M27500B18WK4U00 | National Electrical Mfrs Assn |
5MD1-18A4-UN | Boeing Company, The |
M27500-18WK4U00 | Military Specifications |
M27500B18WK4U00 | Military Specifications |
MIL-C-27500 | Military Specifications |
MIL-DTL-27500 | Military Specifications |