1-321-802-5889

NSN 5945-00-087-0765

Time Delay Relay

About this product

Hermetic environmental protection, 600.0 ohms single winding winding dc resistance rating, continuous duty type, thready qty per inch (tpi): 40 single mounting facility.

Manufacturer part number BR8-600B4S7 for national stock number 5945000870765.

Datasheet

  • Product description

    Electromagnetic Relay NSN 5945-00-087-0765.

  • MPN or Model

    BR8-600B4S7

  • Schedule B
    8536.49.0050 (Relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Unit Weight (Est.)
    0.1 lb
  • Thread Class
    2a single mounting facility
  • Overall Length
    1.060 inches
  • Center To Center Distance Between Mounting Facilities Parallel To Length
    0.484 inches single mounting facility
  • Center To Center Distance Between Mounting Facilities Parallel To Width
    0.234 inches single mounting facility
  • Overall Height
    0.790 inches
  • Overall Width
    0.790 inches
  • Environmental Protection
    Hermetic
  • Winding Quantity
    1
  • Coil Quantity
    1
  • Winding Dc Resistance Rating
    600.0 ohms single winding
  • Duty Type
    Continuous
  • Mounting Facility Type And Quantity
    2 threaded stud single mounting facility
  • Features Provided
    Polarized
  • Thready Qty Per Inch (tpi)
    40 single mounting facility
  • Thread Size
    0.112 inches single mounting facility
  • Mounting Facility Pattern
    Diagonal single mounting facility
  • Nonpile-up Main Contact Arrangement
    2 pole, double throw, one position momentary
  • Operating Current Rating And Type
    40.0 milliamperes dc single winding
  • Operating Voltage Rating And Type At Specificationified Temp
    26.0 volts dc 25 degrees celsius single winding
  • Main Contact Load Current Rating At Maximum Rated Voltage
    2.0 amperes ac resistive load and 2.0 amperes dc resistive load
  • Main Contact Maximum Voltage Rating In Volts
    115.0 ac and 28.0 dc
  • Thread Series Designator
    Unc single mounting facility
  • Terminal Type And Quantity
    8 pin all functions
More from these suppliers
Electromagnetic Relay

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.

Mechanic Bill explains Time Delay Relay

Pricing and Availability

Get a quote for 5945-00-087-0765 electromagnetic relay
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5945000870765

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
BR8-600B4S7 Esterline Electronics Corp
271MS115P003 Raytheon Co
271MS115P003 Raytheon Company
271MS115P003 Raytheon Company
3SAE1122A2 Tyco Electronics Corporation
MV7142 Elgin National Industries Inc
3SAE1122A2 Tyco Electronics Corporation
68GB4N-4-F-600-1 Electronic Specialty Corp
271MS115P003 Raytheon Company
Stock Check