1-321-802-5889

NSN 5945-00-188-5624

Time Delay Relay

About this product

255.0 ohms single winding winding dc resistance rating, continuous duty type, diagonal single mounting facility mounting facility pattern, nonpile-up main contact arrangement: 2 pole, single throw, normally open, momentary action.

Manufacturer part number 7611196P25 for national stock number 5945001885624.

Datasheet

  • Product description

    Electromagnetic Relay NSN 5945-00-188-5624.

  • MPN or Model

    7611196P25

  • Schedule B
    8536.41.0020 (Relays, electromechanical, with contacts rated less than 10 a, for a voltage not exceeding 60 v)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Unit Weight (Est.)
    0.2 lb
  • Thread Class
    2a single mounting facility
  • Overall Length
    1.710 inches
  • Center To Center Distance Between Mounting Facilities Parallel To Length
    0.437 inches single mounting facility
  • Center To Center Distance Between Mounting Facilities Parallel To Width
    0.250 inches single mounting facility
  • Overall Height
    2.370 inches
  • Overall Width
    0.870 inches
  • Winding Quantity
    1
  • Coil Quantity
    1
  • Winding Dc Resistance Rating
    255.0 ohms single winding
  • Duty Type
    Continuous
  • Mounting Facility Type And Quantity
    2 threaded stud single mounting facility
  • Thread Size
    0.138 inches single mounting facility
  • Mounting Facility Pattern
    Diagonal single mounting facility
  • Nonpile-up Main Contact Arrangement
    2 pole, single throw, normally open, momentary action
  • Operating Current Rating And Type
    90.0 milliamperes dc single winding
  • Operating Voltage Rating And Type At Specificationified Temp
    24.0 volts dc 25 degrees celsius single winding
  • Main Contact Load Current Rating At Maximum Rated Voltage
    5.0 amperes dc resistive load
  • Main Contact Maximum Voltage Rating In Volts
    24.0 dc
  • Thread Series Designator
    Unc single mounting facility
  • Terminal Type And Quantity
    8 pin all functions
More from these suppliers
Electromagnetic Relay

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.

Mechanic Bill explains Time Delay Relay

Pricing and Availability

Get a quote for 5945-00-188-5624 electromagnetic relay
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5945001885624

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
7611196P25 Westinghouse Electric Corp
7414259-104 Westinghouse Electric Corp
BJ6D24VDC Allied Controls, Inc.
BJ6D36 Allied Controls, Inc.
Stock Check