Hermetic environmental protection, moderately rugged fragility factor, general purpose for which designed, winding dc resistance rating: 630.0 ohms single winding and 770.0 ohms single winding.

Manufacturer part number HFW1206K03 for national stock number 5945010427382.

Picture of NSN 5945-01-042-7382

Datasheet

  • Product description

    Electromagnetic Relay NSN 5945-01-042-7382.

  • MPN or Model

    HFW1206K03

  • Schedule B
    8536.49.0050 (Relays, electromechanical, with contacts rated at less than 10 a, for a voltage exceeding 60 v but not exceeding 1000 v)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Unit Weight (Est.)
    0.1 lb
  • Overall Length
    1.180 inches
  • Center To Center Distance Between Mounting Facilities Parallel To Length
    1.000 inches single mounting facility
  • Overall Height
    0.620 inches
  • Overall Width
    0.400 inches
  • Environmental Protection
    Hermetic
  • Unthreaded Mounting Hole Diameter
    0.096 inches single mounting facility
  • Fragility Factor
    Moderately rugged
  • Winding Quantity
    1
  • Purpose For Which Designed
    General
  • Coil Quantity
    1
  • Winding Dc Resistance Rating
    630.0 ohms single winding and 770.0 ohms single winding
  • Duty Type
    Continuous
  • Arc Quenching Method
    Air
  • Mounting Facility Type And Quantity
    2 unthreaded hole single mounting facility
  • Storage Type
    General purpose warehouse
  • Mounting Facility Pattern
    In-line single mounting facility
  • Nonpile-up Main Contact Arrangement
    2 pole, double throw, one position momentary
  • Time Delay
    0.003 seconds fixed release time
  • Operating Voltage Rating And Type At Specificationified Temp
    26.0 volts dc 25 degrees celsius single winding
  • Main Contact Load Current Rating At Maximum Rated Voltage
    2.0 amperes ac resistive load and 2.0 amperes dc resistive load
  • Main Contact Maximum Voltage Rating In Volts
    115.0 ac and 28.0 dc
  • Energizing Element Power Rating
    175.0 milliwatts
  • Terminal Type And Quantity
    8 pin all functions
More from these suppliers
Electromagnetic Relay

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.

Mechanic Bill explains Time Delay Relay

Pricing and Availability

Get a quote for 5945-01-042-7382 electromagnetic relay
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5945010427382

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
HFW1206K03 Tyco Electronics Corporation
BACR13CD2 The Boeing Company
HFW1204K01 Tyco Electronics Corporation
3SAV1338A2 Communications Instruments Inc
3SAV1338A2 Genicom Corp
BR16-S233 Esterline Electronics Corp
HFW1204K01 Cp Clare Corp
HFW1206K03 Tyco Electronics Corporation
HFW1204K01 Tyco Electronics Corporation
Stock Check
Availability for this item was last checked on 04/22/24. The quantities and conditions available at the time were:
  • AR: 2
  • NS: 21
  • NE: 356
  • SV: 4
  • OH: 1