NSN 5945-01-169-4126
Time Delay Relay
About this product
Shock resistant and vibration resistant environmental protection, moderately rugged fragility factor, 180.0 ohms single winding winding dc resistance rating, duty type: continuous.
Manufacturer part number 910193-1 for national stock number 5945011694126.
Datasheet
-
Product description
Electromagnetic Relay NSN 5945-01-169-4126.
-
MPN or Model
910193-1
-
Schedule B
8536.49.0075 (Relays, electromechanical, for a voltage exceeding 60 v but not exceeding 1, 000 v, nesoi) -
Thread Class
2a single mounting facility -
Thread Direction
Right-hand single mounting facility -
Thread Length
0.375 inches single mounting facility -
Overall Length
1.531 inches -
Center To Center Distance Between Mounting Facilities Parallel To Length
1.187 inches single mounting facility -
Center To Center Distance Between Mounting Facilities Parallel To Width
1.187 inches single mounting facility -
Overall Height
2.218 inches -
Overall Width
1.531 inches -
Environmental Protection
Shock resistant and vibration resistant -
Fragility Factor
Moderately rugged -
Winding Quantity
1 -
Coil Quantity
1 -
Winding Dc Resistance Rating
180.0 ohms single winding -
Duty Type
Continuous -
Mounting Facility Type And Quantity
4 threaded stud single mounting facility -
Storage Type
General purpose warehouse -
Cubic Measure
5.199 cubic inches -
Thready Qty Per Inch (tpi)
32 single mounting facility -
Thread Size
0.138 inches single mounting facility -
Mounting Facility Pattern
Rectangular single mounting facility -
Nonpile-up Main Contact Arrangement
4 pole, double throw, one position momentary -
Operating Current Rating And Type
100.0 milliamperes dc single winding -
Time Delay
0.02 seconds fixed operate and release time -
Operating Voltage Rating And Type At Specificationified Temp
50.0 volts dc 25 degrees celsius single winding -
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes ac motor load and 4.0 amperes dc motor load -
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc -
Thread Series Designator
Unc single mounting facility -
Terminal Type And Quantity
14 wire hook all functions
More from these suppliers
- 5935-00-139-2777 MPN 5550563-4Electrical Receptacle Connector
- 4820-00-313-9615 MPN 820-4383956GP3Vented Cap Assembly
- 4820-00-375-8657 MPN 228-59-05PC462-24Globe Valve Parts Kit
- 4820-00-482-8906 MPN 810-1385721 1/4INCheck Valve
- 4820-00-780-5301 MPN 820-2178731-1Globe Valve
- 5985-00-927-9873 MPN 1651742-1Waveguide Assembly
- 5905-00-960-7345 MPN 12Z13110-904Inductive Wire Wound Fixed Resistor
- 5905-01-005-2276 MPN 2901688-18Nonprecision Nonwire Wound Variable Resistor
Electromagnetic Relay
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.
![Mechanic Bill explains Time Delay Relay](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5945-01-169-4126 electromagnetic relayManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
910193-1 | Naval Sea Systems Command |
9224-8153-50VDC | Leach International Corporation |
Stock Check
![](/public/images/partscage_shelf3.png)
Availability of this NSN has not been updated recently. Submit
the pricing and availbility form above to receive an up to date quote.