NSN 5925-00-019-2389
Overload Switch
Multipole-single actuator type body style, plastic case material, 3 poles, storage type: general purpose warehouse.
Manufacturer part number TKM836Y800 for national stock number 5925000192389.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-019-2389.
-
MPN or Model
TKM836Y800
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Body Length
15.000 inches -
Body Width
8.250 inches -
Body Height
5.500 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
14.250 inches -
Center To Center Distance Between Terminals Parallel To Width
1.375 inches -
Unthreaded Mounting Hole Diameter
0.250 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
14.250 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.750 inches -
Boss Height
0.219 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
4 unthreaded hole -
Storage Type
General purpose warehouse -
Features Provided
Adjustable trip release -
Maximum Continuous Load Current Rating Per Pole
800.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
22000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Adjustable Trip Setting Current Range Per Pole In Amps
+125.0 to 800.0 ac all locations -
Trip Delay Time In Seconds Per Rated Continuous Current
35.000 at 300 pct all locations and 175.000 at 300 pct all locations -
Inclosure Protection Type For Which Designed
Dustproof -
Trip Release Ambient Tempurature Rating
40.0 degrees celsius all locations -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
6 compression
More from these suppliers
- 5945-00-312-4884 MPN IC5882C3BThermal Relay
- 5945-00-941-5866 MPN 121BCG51E23AElectromagnetic Relay
- 5945-01-160-0892 MPN IC5182D120A6ABBAElectromagnetic Relay
- 5930-01-200-7476 MPN 16SB1BA210Rotary Switch
- 5945-01-221-9843 MPN P-8290517G2Electromagnetic Relay
- 6105-01-127-0042 MPN 5K47UG8073Alternating Current Motor
- 6105-01-213-2760 MPN 5K405NN4001Alternating Current Motor
- 5925-00-833-8288 MPN TKMA836T800Circuit Breaker Tripper
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-019-2389 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
TKM836Y800 | General Electric Co |
TKM836Y800 | General Electric Co |