NSN 5925-00-059-2838
Overload Switch
Multipole-multiple actuator type body style, metal case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number 930-012-705 for national stock number 5925000592838.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-059-2838.
-
MPN or Model
930-012-705
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Bushing Length
0.250 inches -
Body Length
2.250 inches -
Body Width
1.218 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.704 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
2.218 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
3 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
7.5 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1200.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 push-pull -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.469 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 at 200 pct all locations and 55.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Hermetically sealed and shock resistant and vibration resistant -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius all locations -
Frequency In Hertz
400.0 all locations -
Unpackaged Unit Weight
150.0 grams -
Test Data Document
76374-ft-12 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing) -
Thread Series Designator
Uns -
Terminal Type And Quantity
2 tab w/screw
More from these suppliers
- 5925-00-729-0576 MPN 700-002-705Circuit Breaker
- 5925-01-661-5945 MPN 1536-013-15Circuit Breaker
- 5930-00-058-4918 MPN W20170-004Push Switch
- 5950-00-232-8021 MPN 81046W1ITEM31Electrical Coil
- 5930-00-258-5668 MPN C1008RPush Switch
- 5945-00-406-4242 MPN 6047H6Electromagnetic Relay
- 5930-00-655-1514 MPN 8801K22Toggle Switch
- 5930-00-683-4911 MPN E4-271Sensitive Switch
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-059-2838 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
930-012-705 | Labinal, Llc |
MP932B | Labinal, Llc |
930-012-705 | Labinal, Llc |