1-321-802-5889

NSN 5925-00-211-2311

Overload Switch

About this product

Multipole-single actuator type body style, plastic case material, 3 poles, maximum continuous load current rating per pole: 60.0 amperes ac all locations and 60.0 amperes dc all locations.

Manufacturer part number FHB36060 for national stock number 5925002112311.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-00-211-2311.

  • MPN or Model

    FHB36060

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Unit Weight (Est.)
    0.1 lb
  • Body Style
    Multipole-single actuator type
  • Body Length
    6.000 inches
  • Body Width
    4.469 inches
  • Body Height
    3.000 inches
  • Case Material
    Plastic
  • Center To Center Distance Between Terminals Parallel To Length
    5.125 inches
  • Center To Center Distance Between Terminals Parallel To Width
    1.500 inches
  • Unthreaded Mounting Hole Diameter
    0.172 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
    5.125 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
    1.500 inches
  • Boss Height
    0.156 inches
  • Pole Quantity
    3
  • Mounting Facility Type And Quantity
    4 unthreaded hole
  • Maximum Continuous Load Current Rating Per Pole
    60.0 amperes ac all locations and 60.0 amperes dc all locations
  • Operating Voltage Type And Rating Per Pole In Volts
    600.0 ac all locations and 250.0 dc all locations
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    15000.0 ac all locations and 10000.0 dc all locations
  • Circuit Protection Type
    Overcurrent all locations
  • Trip Release Method
    Thermal-magnetic all locations
  • Trip Release Characteristic
    Instantaneous all locations and time delay all locations
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    138.0 all locations
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    1 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At pole two
  • Trip Delay Time In Seconds Per Rated Continuous Current
    40.000 at 200 pct all locations and 125.000 at 200 pct all locations
  • Trip Release Ambient Tempurature Rating
    40.0 degrees celsius all locations
  • Frequency In Hertz
    60.0 all locations
  • Terminal Type And Quantity
    6 compression
More from these suppliers
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-00-211-2311 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925002112311

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
FHB36060 Schneider Electric Usa, Inc.
FHB36060 Schneider Electric Usa, Inc.
Stock Check